Artroscopia Pediatrica

Artroscopia Pediatrica

domingo, 31 de mayo de 2015

Sever’s Disease

#Sever’s Disease
Fuente
Este artículo es originalmente publicado en:
http://orthopaedicprinciples.com/2015/05/severs-disease-2/

https://youtu.be/f9NmYF47fGs
De:
Courtesy: Prof Nabile Ebraheim, University of Toledo, Ohio, USA
Todos los derechos reservados para:
Copyright@orthopaedicprinciples.com. All right rerserved.


Publicado el 20/05/2015
Educational video describing the condition of Sever's disease.


sábado, 30 de mayo de 2015

Sindrome de embolismo graso / Fat Embolism Syndrome

#Fat Embolism Syndrome #Sindrome de embolismo graso
Fuente
Este artículo es originalmente publicado en:
http://www.patient.co.uk/doctor/fat-embolism-syndrome


viernes, 29 de mayo de 2015

Alineación coronal en el reemplazo total de rodilla: reseña histórica, el análisis contemporáneo, y la dirección futura / Coronal alignment in total knee replacement: historical review, contemporary analysis, and future direction

#Coronal alignment #Alineación coronal #reemplazo total de rodilla #total knee replacement

Fuente
Este artículo es originalmente publicado en:
http://www.ncbi.nlm.nih.gov/pubmed/24986936?dopt=Abstract
http://www.bjj.boneandjoint.org.uk/content/96-B/7/857.abstract
De:
Abdel MP1Oussedik S2Parratte S3Lustig S4Haddad FS.
 2014 Jul;96-B(7):857-62. doi: 10.1302/0301-620X.96B7.33946
Todos los derechos reservados para:
©2014 The British Editorial Society of Bone & Joint Surgery


Abstract


Substantial healthcare resources have been devoted to computer navigation and patient-specific instrumentation systems that improve the reproducibility with which neutral mechanical alignment can be achieved following total knee replacement (TKR). This choice of alignment is based on the long-held tenet that the alignment of the limb post-operatively should be within 3° of a neutral mechanical axis. Several recent studies have demonstrated no significant difference in survivorship when comparing well aligned versus malaligned TKRs. Our aim was to review the anatomical alignment of the knee, the historical and contemporary data on a neutral mechanical axis in TKR, and the feasibility of kinematically-aligned TKRs. Review of the literature suggests that a neutral mechanical axis remains the optimal guide to alignment.




Resumen

Recursos sanitarios sustanciales se han dedicado a la navegación del ordenador ysistemas de instrumentación de pacientes específicos que mejoran la reproducibilidadcon la que la alineación mecánica neutro se puede lograr después del reemplazo total de rodilla (PTR). Esta elección de la alineación se basa en el principio de larga data de que la alineación de la extremidad después de la operación debe ser menos de 3 ° de un eje mecánico neutral. Varios estudios recientes han demostrado diferencias significativas enla supervivencia cuando se comparan bien alineados frente TKRs mal alineados. Nuestro objetivo fue revisar la alineación anatómica de la rodilla, los datos históricos y contemporáneos en un eje mecánico neutral en TKR, y la factibilidad de TKRscinemáticamente alineados. Revisión de la literatura sugiere que un eje mecánico neutralsigue siendo la guía óptima para la alineación.

©2014 The British Editorial Society of Bone & Joint Surgery.

KEYWORDS:

Total knee replacement; Coronal alignment; Neutral mechanical alignment; Anatomic alignment; Kinematically aligned total knee replacement
PMID:
 
24986936
 
[PubMed - indexed for MEDLINE]

jueves, 28 de mayo de 2015

Espectroscopia de bioimpedancia para evaluación de la inflamación después de una artroplastia total de rodilla: un estudio de validación / Bioimpedance spectroscopy for swelling evaluation following total knee arthroplasty: a validation study

#total knee arthroplasty #Bioimpedance spectroscopy

Fuente
Este artículo es originalmente publicado en:
http://www.ncbi.nlm.nih.gov/pubmed/25907994
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4422299/
http://www.biomedcentral.com/1471-2474/16/100
De:
Pichonnaz C1,2Bassin JP3Lécureux E4Currat D5Jolles BM6.
 2015 Apr 25;16:100. doi: 10.1186/s12891-015-0559-5
Todos los derechos reservados para:
© 2015 Pichonnaz et al.; licensee BioMed Central. 
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.


Abstract

BACKGROUND:

The evaluation of swelling is important for the outcome of total knee arthroplasty (TKA) surgery. The circumference or volume measurements are applicable at the bedside of the patient but are altered by muscular atrophy and the post-surgical dressing. Bioimpedance spectroscopy might overcome these limitations; however, it should be validated. This study aimed to explore the validity, the reliability and the responsiveness of bioimpedance spectroscopy for measuring swelling after TKA.

CONCLUSION:
Bioimpedance is a valid method for the evaluation of swelling following TKA. BIS R0 also demonstrated excellent intra- and inter- evaluator reliability. The diagnostic sensitivity and responsiveness is superior to that of concurrent methods. BIS R0 is an efficient method for post-surgical follow up at the bedside of the patient. The measurement of BIS R0 is a straightforward, valid, reliable and responsive method for lower limb swelling following TKA surgery that could be used in clinics and research.

Resumen

ANTECEDENTES:
La evaluación de la inflamación es importante para el resultado de la cirugía de artroplastia total de rodilla (TKA). Las mediciones de la circunferencia o volumen son aplicables a la cabecera del paciente, pero se alteran por la atrofia muscular y el apósito post-quirúrgico. La espectroscopia de bioimpedancia podría superar estas limitaciones; sin embargo, debe ser validada. Este estudio tuvo como objetivo explorar la validez, la fiabilidad y la capacidad de respuesta de la espectroscopia de bioimpedancia para medir la inflamación después de la ATR.

CONCLUSIÓN:
La bioimpedancia es un método válido para la evaluación de la inflamación después de TKA. BIS R0 también demostró tener una excelente fiabilidad intra e inter evaluador. La sensibilidad de diagnóstico y capacidad de respuesta es superior a la de los métodos concurrentes. BIS R0 es un método eficaz para el 
seguimiento post-quirúrgico  de la cabecera del paciente. La medición de BIS R0 es un método sencillo, válido, fiable y sensible para la inflamación de las extremidades inferiores después de una cirugía de TKA que se podría utilizar en clínicas y de investigación.

TRIAL REGISTRATION:

ClinicalTrials.gov Identifier: NCT00627770 .
PMID:
 
25907994
 
[PubMed - in process] 
PMCID:
 
PMC4422299
 
Free PMC Article

Hip fracture drug prevention strategies are 'pointless'

Fuente
Este artículo es originalmente publicado en:
http://www.medicalnewstoday.com/articles/294469.php?utm_medium=twitter&utm_source=Twitter+for+iPhone

De:
Written by Markus MacGill

Todos los derechos reservados para:

Copyright: Medical News Today


FDA warns Signal Medical on unapproved hip implants

Overdiagnosis of bone fragility in the quest to prevent hip fracture


Fuente
Este artículo es originalmente publicado en:
http://www.bmj.com/content/350/bmj.h2088
De
  1. Teppo LN Järvinen, professor1
  2. Karl Michaëlsson, professor2
  3. Jarkko Jokihaara, registrar3
  4. Gary S Collins, associate professor4
  5. Thomas L Perry, clinical assistant professor5
  6. Barbara Mintzes, senior lecturer6
  7. Vijaya Musini, assistant professor5
  8. Juan Erviti, head7
  9. Javier Gorricho, senior evaluation officer8
  10. James M Wright, professor5
  11. Harri Sievänen, research director9
    Todos los derechos reservados para:
    Copyright © 2015 BMJ Publishing Group Ltd